Cut-off current: 0.01 C. Standard discharge: Constant current 0.2C5A end voltage 10.0V. Maximum discharge continuous current: 30A.
Cell overcharge detection voltage:3.90V±50mV. Cell overcharge recovery voltage:3.80V±100mV. Cell over-discharge detection voltage:2.00V±100mV. Cell over-discharge recovery voltage:2.50V±100mV. Rated operational charge current:30A. 12.8V 50Ah Lithium Iron batteries. MODEL: 50Ah 12.8V(4S9P). Maximum discharge continuous current: 50A. Cell over-discharge recovery voltage:2.30V±100mV. Rated operational charge current:50A. 12.8V 100Ah Lithium Iron batteries. MODEL: 100Ah 12.8V(4S1P).Maximum discharge continuous current: 100A. Rated operational charge current:100A.
12.8V 150Ah Lithium Iron batteries. MODEL: 150Ah 12.8V(4S3P). Maximum discharge continuous current: 150A. Rated operational charge current:150A. The BMS it supports up to 51.2V series or 16 parallel installations of the same voltage and same capacity (4S4P), please fully charge the batteries before series/parallel installation to ensure that each battery is at the same voltage and same capacity.