48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV

48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV

48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV    48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV

51.2V 100Ah LifePO4 Battery Class A High-power Home & RV Backup Power Supply. Programmable Smart BMS: Individual cell status can be monitored.

6 Temperature Sensors: Detects cells, environment, power MOS temperature, alerts and protects when charging and discharging at high or low temperature. This rechargeable LiFePO4 battery has 3 charging methods, you can choose the charger, or you can use solar energy. Smaller Size: 1 51.2V 100Ah battery = 4 12.8 100Ah battery. The LCD screen will display the voltage, current, temperature and SOC of the server rack battery as it charges and discharges. Compatible With 20 Types of Inverters. Aolithium server rack batteries are compatible with Pylontech, GoodWe, Deye, Megarevo, Victron and 20 other inverters. For parallel communication operation of multiple server rack batteries, dial-up address configuration is required.

Our server rack batteries meet address 16, address 32, address 48. No fear of extreme weather.

Under the protection of BMS, lithium iron phosphate batteries can discharge normally even in extremely cold weather. Charging temperature 32°F to 131°F. Discharge temperature -4°F to 140°F. Storage temperature: 14°F to 86°F. Server Rack Battery Requirements Accessory List.

AK01 Long Cable Kit Includes. RJ45 communication cable (PCS) 1. RJ45 communication cable (cascade) 1. RJ45 communication cable (master slave) 1.

M5 hexagon socket head screws 4. The best alternative to lead-acid batteries, why hesitate if it does a better job? Improve your lifestyle and change your travel life. Longer Life & Deep Cycle: More than 20 years of design life, more than 4,000 cycles at 90% DOD, better than lead-acid batteries in terms of safety and stability.

Class A square Lifep4 Battery: Support parallel expansion. Higher energy density, lighter weight, smaller size, and does not contain any heavy metals and rare metals, making it more environmentally friendly. LCD Screen: Real-time monitoring of battery voltage, current, temperature and SOC during charging and discharging. Rack-mounted Design: There is a pair of portable handles on the front to help you better move your solar energy storage system. BMS Battery: Provides 15 safety detection and protection functions, including temperature detection, voltage protection, short circuit protection, etc.

Providing you with 100% safety protection. Series and Parallel Connection: Supports 4 batteries in parallel. 1 51V100ah Lifepo4 Battery(Does not include connecting cable).

About SERIES AND PARALLEL CONNEC. 488578177.8mm(With handle and fixed bracket). Please observe the following safety rules when using batteries, Abuse of batteries can leadto overheating, bulging and fire of batteries and cause serious damage. DO NoT disassemble or modify the battery. DO NoT short circuit positive and negative terminals.

DO NOT puncture, drop, crush, burn, penetrate, shake, or strike the battery. DO NOT expose to the environment, this battery is not sealed. Please keep the batteryaway from water, heat sources, sparks, and hazardous chemicals. DO NoT dispose of the battery as household waste. Please use recycling channels inaccordance with local, state, and federal regulations. Only charge the battery with a battery charger or charge controller that iscompatible with lithium iron phosphate batteries. Lf the battery shuts off due to a low state of charge, please disconnect the battery fromyour equipment to eliminate parasitic loads and charge the battery as soon as possible. Please wear proper protective equipment when working on the battery. Please use insulated tools when working on the battery.

Please keep the battery out of the reach of young children. Each battery pack must be fully charged independently before connecting. Please makesure that the voltage difference of each battery pack is within 0.3V before connecting inparallel. All batteries should be at the same charge level prior to connection or you willexperience balancing problems in your system. DO NoT connect batteries in series!

Lf you need more than 4 batteries in parallel. Please contact our customer service andwe will give you professional guidance.

This model can be connected with up to 16 units 51.2V100Ah batteries in parallel. Parallel ConnectingTotal voltage and capacity: 51.2V 1600Ah. All cables and connections must be able to accommodate the high currentsthat can be supplied by the battery.

The use of appropriate fuses and circuit breakers ishighly recommended to protect downstream components from current spikes and shortcircuits. In parallel battery banks, the cables between each battery should be of equal length toensure that all batteries in the system can work equally together.

To connect multiple batteries in parallel, first connect the positive terminals of thebatteries to each other. Then do the same thing for the negative terminal. After the above connections are made, connect the positive and negative terminals of thefirst battery to the system. This type of arrangement is used to increase the overallbattery capacity while maintaining the same voltage. DO NOT string batteries with different chemistries, models, rated capacity in series orparallel.

Only dry powder fire or carbon dioxide extinguisher can be used; if possible, move the battery pack to a safe area before it catches fire. 1 lt is required to charge the battery at least once every 3 months, for this chargemaintenance make sure the SOC is charged to higher than90%.

The connection of power connector, grounding point. Power cable and screw are suggested to be checked.

Make sure there is no loose, nobroken, no corrosion at connection point. Check the installation environment such asdust, water, insect etc. Make sure it is suitable for lP20 battery system. 3 lf the battery is stored for long time, it is required to charge them every six months, and the SOC should be higher than 90%.

We will do our best to provide you with after-sales service composed of the most professional customer service and engineers. By the way, we hope to provide you with a 100% satisfactory shopping experience. If you are satisfied with our products, please leave us your feelings and views. But if you have any questions, please do not open CASE directly, we We can solve your problem directly and faster.

Thank you and wish you a happy day.
48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV    48V 100Ah Server Rack Lithium LiFePO4 Battery BMS Deep Cycle LCD 5.12kWh RV